Fault codes Remeha

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

Sometimes a number follows the code (6A 227): type it too, the page shows what it means.

Your brand

Your boiler Remeha

The model is written on the rating plate, often under the cover.

All codes Remeha

A.00.00 Flow temperature sensor disconnected
A.00.01 Flow temperature sensor short-circuited
A.00.107 Cylinder bottom sensor short-circuited
A.00.108 Cylinder bottom sensor open
A.00.28 Solar temperature sensor disconnected
A.00.29 Solar temperature sensor short-circuited
A.00.32 Outdoor sensor missing or open circuit
A.00.33 Outdoor sensor short-circuited
A.00.40 Water pressure low or not measured
A.00.57 Cylinder top sensor open
A.00.58 Cylinder top sensor short-circuited
A.01.21 Temperature rising too fast on hot water
A.02.54 OpenTherm bus power supply error
A.02.96 Anti-legionella cycle not completed
A.03.17 Safety check in progress
A.08.06 LIN pump 1 running under limitations
A.10.33 Hot water cylinder top sensor disconnected
A.10.34 Hot water cylinder top sensor short-circuited
A.10.45 Zone A room sensor missing
A.10.46 Zone B room sensor missing
A.10.47 Zone C room sensor missing
A.10.50 Hot water cylinder top sensor missing
A.10.54 Hot water zone sensor missing
A.10.56 AUX zone hot water sensor missing
A00.34 Outdoor sensor expected but not detected
A00.42 Water pressure sensor not detected
A01.23 Poor combustion: flame lost while running
A02.06 Water pressure in the heating too low
A02.18 Circuit board configuration error
A02.33 Automatic filling takes too long
A02.34 Automatic filling needed too often
A02.36 Connected functional device disconnected
A02.37 Non-critical device disconnected
A02.45 Connection problem on the communication bus
A02.46 Error managing the connected devices
A02.48 Function group configuration error
A02.49 Connected device initialisation failed
A02.55 Serial number missing or invalid
A02.69 Demonstration mode is active
A02.76 Custom settings memory full
A02.80 Bus not terminated or cascade controller missing
A05.29 Gas pressure below the limit
A05.30 Gas pressure check failed
A05.95 Brief interruption of the flame signal
A08.02 Shower time elapsed
Code de blocage 1 Green light once: temperature protection
Code de blocage 2 Green light twice: blocking input
Code de blocage 3 Green light three times: flame lost
Code de blocage 4 Green light four times: communication fault
Code de blocage 5 Green light five times: parameter error
Code de blocage 6 Green light six times: other blocking codes
Code de défaut 1 Red light once: sensor fault
Code de défaut 2 Red light twice: maximum protection
Code de défaut 3 Red light three times: ignition fault
Code de défaut 4 Red light four times: fan fault
Code de défaut 5 Red light five times: parameter fault
Code de défaut 6 Red light six times: other faults
E.00.00 Flow sensor missing or open circuit
E.00.01 Flow sensor short-circuited
E.00.08 Heat exchanger sensor disconnected
E.00.09 Heat exchanger sensor short-circuited
E.00.18 Hot water tank sensor not detected
E.00.20 Flue gas temperature sensor open
E.00.21 Flue gas temperature sensor short-circuited
E.02.04 Boiler parameter error
E.02.48 Function group configuration error
E.02.52 Burner profile error
E.02.70 Heat recovery unit test failed
E.02.90 Boiler room ventilation timed out
E.04.09 Mismatch between the two flue gas sensors
E00.04 Return temperature sensor disconnected
E00.05 Return temperature sensor short-circuited
E00.06 Return temperature sensor not detected
E00.07 Return too hot or flow-return difference too large
E00.16 Hot water tank sensor open or missing
E00.17 Hot water tank sensor short-circuited
E00.40 Water pressure sensor open or missing
E00.41 Water pressure sensor short-circuited
E00.44 Domestic hot water sensor open
E00.45 Domestic hot water sensor short-circuited
E01.04 Flame lost five times
E01.11 Fan speed out of range
E01.12 Return warmer than the flow
E01.17 No water circulation detected
E01.20 Maximum flue gas temperature reached
E01.24 Too many combustion errors in 24 hours
E02.13 Boiler locked by an external device
E02.15 CSU configuration key not recognised
E02.17 Circuit board communication error
E02.32 Automatic filling took too long
E02.35 Critical safety device disconnected
E02.39 Pressure too low after automatic filling
E02.47 Connection to a connected device failed
E02.78 Hot and cold water connections swapped
E04.00 Error in the safety parameters
E04.01 Flow temperature sensor short-circuited
E04.02 Flow temperature sensor open or disconnected
E04.03 Maximum flow temperature exceeded
E04.04 Flue gas temperature sensor short-circuited
E04.05 Flue gas temperature sensor open or disconnected
E04.06 Critical flue gas temperature reached
E04.07 Too large a difference between flow sensors
E04.08 Safety input open or overheating
E04.10 The burner fails to light
E04.11 Gas valve leak test failed
E04.12 False flame detected by the boiler
E04.13 Boiler fan fault
E04.14 Burner combustion fault
E04.15 Flue gas outlet blocked
E04.17 Gas valve control fault
E04.18 Flow temperature below the minimum
E04.23 Internal control error
E04.24 Gas type not recognised
E04.25 Flame lost during the safety time
E04.250 Gas valve or gas valve relay fault
E04.254 Unknown boiler error
E04.26 Burner ignition error
E04.27 Gas valve open with flame detected
E04.28 Gas valve feedback fault
E04.29 Maximum number of resets reached
E04.50 Gas valve fault
E04.54 Unknown error or gas valve control
E13 Heat exchanger overheat fuse tripped
E43 Parameters outside their limits
E44 Parameter check failed
E45 Default parameters cannot be restored
E:00 Parameter unit not found or sensor fault
E:01 Safety parameters wrong or flow too hot
E:02 Sensor short circuit or return too hot
E:03 Flow sensor open or electrical fault
E:04 Heat exchanger too cold or no flame
E:05 Heat exchanger too hot or ionisation fault
E:06 Return sensor short circuit or stray flame
E:07 Return sensor open or no water
E:08 Return too cold or fan fault
E:09 Return too hot or no water
E:10 Temperature difference or no water flow
E:11 Temperature difference or air box too hot
E:12 Overheating, siphon or ventilation unit
E:14 Five failed burner starts
E:15 Five failed gas leak tests
E:16 False flame signal
E:17 Gas valve control fault
E:32 Flow temperature sensor short-circuited
E:33 Flow temperature sensor open circuit
E:34 Boiler fan fault
E:35 Flow and return reversed
E:36 Five flame losses
E:37 Communication error with the SU board
E:38 Communication error with the SCU board
E:39 Blocking input in lockout mode
E:40 Heat recovery unit (HRU) test error
E:41 Control unit maximum temperature exceeded
F03 Fuse 03 is faulty
H.00.16 Hot water tank sensor disconnected
H.00.17 Hot water tank sensor short-circuited
H.00.36 Second return sensor disconnected
H.00.37 Second return sensor short-circuited
H.00.69 Buffer tank sensor disconnected
H.00.70 Buffer tank sensor short-circuited
H.00.71 Buffer tank top sensor disconnected
H.00.72 Buffer tank top sensor short-circuited
H.00.74 Buffer tank sensor not detected
H.00.75 Buffer tank top sensor not detected
H.00.76 Cascade flow sensor disconnected
H.00.77 Cascade flow sensor short-circuited
H.00.78 Cascade flow sensor not detected
H.01.06 Heat exchanger to flow difference too high
H.01.07 Heat exchanger to return difference too high
H.01.13 Heat exchanger temperature too high
H.01.15 Flue gas temperature too high
H.02.15 External CSU timed out
H.02.16 Internal CSU timeout
H.02.18 Object dictionary error (OBD)
H.02.36 Functional device disconnected
H.02.40 Function not available
H.02.45 CAN connection matrix full
H.02.46 CAN device register full
H.02.48 Function group configuration error
H.02.50 Function group communication error
H.02.55 Serial number missing or invalid
H.02.61 Function not supported by zone A
H.02.62 Function not supported by zone B
H.02.63 Function not supported by zone C
H.02.64 Function not supported by zone D
H.02.65 Function not supported by zone E
H.02.66 Anti-corrosion anode (TAS) not connected
H.02.67 Anti-corrosion anode (TAS) short-circuited
H.02.79 Device lost on the system bus
H.02.80 Cascade controller not found
H.08.08 LIN pump 1 locked out
H.10.00 Zone A flow sensor disconnected
H.10.01 Zone A flow sensor short-circuited
H.10.02 Zone A hot water sensor disconnected
H.10.03 Circuit A hot water sensor short-circuited
H.10.04 Circuit A swimming pool sensor disconnected
H.10.05 Circuit A swimming pool sensor short-circuited
H.10.09 Circuit B flow sensor disconnected
H.10.10 Circuit B flow sensor short-circuited
H.10.11 Circuit B hot water sensor disconnected
H.10.12 Circuit B hot water sensor short-circuited
H.10.13 Circuit B swimming pool sensor disconnected
H.10.14 Circuit B swimming pool sensor short-circuited
H.10.18 Circuit C flow sensor disconnected
H.10.19 Circuit C flow sensor short-circuited
H.10.20 Circuit C hot water sensor disconnected
H.10.21 Circuit C hot water sensor short-circuited
H.10.22 Circuit C swimming pool sensor disconnected
H.10.23 Circuit C swimming pool sensor short-circuited
H.10.27 Hot water zone flow sensor disconnected
H.10.28 Hot water zone flow sensor short-circuited
H.10.29 Hot water zone sensor disconnected
H.10.30 Hot water zone sensor short-circuited
H.10.36 AUX zone flow sensor disconnected
H.10.37 AUX zone flow sensor short-circuited
H.10.38 AUX zone hot water sensor disconnected
H.10.39 AUX zone hot water sensor short-circuited
H00.42 Water pressure sensor fault
H00.81 Room thermostat or sensor not detected
H01.00 Circuit board communication error
H01.05 Flow and return temperature gap too large
H01.08 Flow temperature rising too fast
H01.09 Gas pressure too low (gas pressure switch)
H01.14 Maximum flow temperature exceeded
H01.18 No water circulation
H01.21 Temperature rising too fast in hot water mode
H01.26 Gas pressure too high
H02.00 Boiler reset in progress
H02.02 Boiler configuration missing (CN1, CN2)
H02.03 Configuration error (CN1, CN2)
H02.04 Error in the circuit board settings
H02.05 Configuration memory does not match the board
H02.07 Water pressure too low in the heating
H02.09 Partial block by an external contact
H02.10 Full block by an external contact
H02.12 External release signal missing
H02.31 Automatic water filling required
H02.38 Auto-fill limit reached or no water hardness
H02.70 External heat recovery unit test failed
H02.91 Heating blocked by the multifunction input
H02.92 Hot water blocked by the multifunction input
H02.93 Heating and hot water blocked by multifunction input
H03.00 Safety parameters missing or incorrect
H03.01 Internal circuit board communication error
H03.02 Flame lost during operation
H03.05 Internal block or supply voltage too low
H03.08 False flame detected
H03.09 Supply voltage too low
H03.17 Gas control fault or safety check
H03.254 Unknown circuit board error
H03.26 Boiler calibration requested
H03.28 Synchronisation error (power supply)
H03.31 Flue gas outlet blocked
H03.45 Manual lambda adjustment disabled
H03.54 Unknown error or temporary flame loss
H08.07 Boiler pump fault
H08.09 Communication with the pump lost
H20.36 Manual calibration failed
H20.39 No initial calibration
H20.40 Gas type not configured
Su:0 Error in the parameters
Su:1 Maximum flow temperature exceeded
Su:10 Blocking input active
Su:11 Blocking input or frost protection active
Su:12 Communication error with the HMI board
Su:13 Communication error with the SCU board
Su:14 Water pressure too low
Su:15 Gas pressure too low
Su:16 Configuration error or SU board not recognised
Su:17 Configuration error or wrong default parameters
Su:18 Configuration error or PSU board not recognised
Su:19 Parameters dF and dU unknown
Su:2 Flow temperature rising too fast
Su:20 Configuration procedure in progress
Su:21 Communication error with the SU board
Su:22 Flame lost during operation
Su:24 Gas valve leak test failed
Su:25 Internal error of the SU board
Su:3 Heat exchanger temperature limit exceeded
Su:4 Heat exchanger temperature rising too fast
Su:5 Temperature gap to the return too large
Su:6 Temperature gap in the boiler too large
Su:7 Flow and return temperatures too far apart
Su:8 No release signal received
Su:9 Live and neutral reversed
b Temporary blocking mode
b08 Too little air flow during pre-purge
b24 Return warmer than flow for 10 minutes
b25 Temperature rising too fast
b26 External safety or low gas pressure
b28 The fan is not turning
b29 The fan does not stop
b30 Flow-return difference too large
b38 Air pressure sensor short circuit
b39 Air pressure sensor open circuit
b43 Wrong parameter settings
b45 Water pressure sensor short-circuited
b46 Water pressure sensor open or disconnected
b52 Maximum flue gas temperature exceeded
b61 Air pressure switch does not open
b62 Water pressure too low (optional sensor)
b88 Blocking input open
b94 Heat exchanger far hotter than flow
b99 Boiler release contact open
cl Burner cooling mode
h Forced operation at full power
l Forced operation at low power
t Automatic self-test in progress
0 Boiler on standby, no heat demand
00 False flame signal detected
01 Short circuit in the 24 V circuit
1 Fan purge before or after burning
02 No flame after several start attempts
2 Burner ignition in progress
03 Gas valve not detected or miswired
3 Boiler running, burner on
04 Power cut during a lockout
4 Boiler heating domestic hot water
05 Electrical interference from outside
5 Waiting for the fan before ignition
06 Short circuit between the temperature sensors
6 Control stop, temperature reached
07 Gas valve relay fault
7 Run-on after the burner stops
08 Wrong setting or insufficient air flow
8 Pump run-on after hot water heating
9 Control stop, flow temperature too high
11 Internal communication bus fault
12 External safety device tripped
17 Gas valve monitoring fault
18 Flow temperature too high
19 Return temperature too high
20 Fan speed too high
24 Return warmer than flow
25 Flow temperature rising too fast
28 Fan not running
29 Fan keeps running or wrong signal
30 Flow-return difference too large
31 Flow sensor short circuit
32 Return sensor short circuit
34 Outdoor sensor short circuit
35 Flue gas sensor short circuit
36 Flow sensor disconnected or faulty
37 Return sensor disconnected or faulty
38 Air pressure switch short-circuited
39 Air pressure switch open circuit
40 Flue gas sensor disconnected or faulty
43 Settings outside their range
45 Water pressure sensor short-circuited
46 Water pressure sensor open or disconnected
52 Flue gas temperature too high
61 Air pressure switch does not open
77 Flame lost during operation
83 Heat exchanger temperature too high
86 SMI positions detected together
87 SMI closed position not detected
89 Gas valve leak detected
90 Gas leak detected on valve VA2
91 Air pressure switch error during pre-purge
93 SMI closed and minimum positions together
94 Heat exchanger hotter than the flow
95 Heat exchanger sensor short circuit
96 Heat exchanger sensor disconnected or faulty
97 Heat exchanger temperature too high