Temperature difference or air box too hot
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:11), the difference between flow and return temperatures is too large (on the Gas 210 Eco Pro, between the heat exchanger and the return), because of a sensor or poor water circulation; on an Avanta, Avanta Plus or Avanta Platinum Plus (E11), the sealed air box is too hot because the heat exchanger leaks into it. In both cases the boiler locks out (on a Tzerra M, which has no display, the light on the button then flashes red); for safety, since on an Avanta this code means a heat exchanger leak, do not reset it before our technician has been.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Smell of flue gases? Switch the boiler off, open the windows, leave the premises and call us.
- Do not reset the boiler: call us.
Does your boiler show E:11?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:11
The meaning depends on the boiler: find yours below.
Sealed casing temperature too high
Air box temperature too high
Difference between flow and return temperatures too large
Difference too large between the heat exchanger and the return temperature
The boilers that show this code
What our technician checks
- The flow and return sensors: operation and fitting, replaced if needed (E:11)
- Circulation (direction, pump, valves), bleeding and water pressure (E:11)
- The heating pump and how clean the heat exchanger is (E:11)
- The sight glass seal and the front plate seal (E11)
- How the front plate is fitted and fixed (E11)
- How the ignition electrode is fitted (E11)