Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E:04

Heat exchanger too cold or no flame

Breakdown: the boiler is stopped

This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:04), the heat exchanger temperature is too low, because of a badly connected or faulty sensor or water that is not circulating; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E04), the burner has not lit after several start attempts (up to 5): no spark, a spark without a flame, or a flame detected too weakly. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On an Avanta or Aquanta: check that the boiler's gas tap is open; if it is closed, open it.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E:04?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E:04

The meaning depends on the boiler: find yours below.

E04

No flame detected (After a long period without use, up to 5 start attempts may

Breakdown: the boiler is stopped Avanta Plus
E04

No flame formed after the 5th start

Breakdown: the boiler is stopped Avanta Platinum Plus
E04

More than 5 start attempts without flame formation.

Breakdown: the boiler is stopped Aquanta, Avanta
E:04

Heat exchanger temperature too low

Breakdown: the boiler is stopped Calenta, Quinta Pro, Tzerra M
E:04

Heat exchanger temperature within the normal range

Breakdown: the boiler is stopped Gas 210 Eco Pro

The boilers that show this code

What our technician checks

  • The heat exchanger sensor's wiring and fitting, replaced if needed (E:04)
  • Circulation (direction, pump, valves), bleeding and water pressure (E:04)
  • How clean the heat exchanger is, and the boiler type parameter (E:04)
  • The ignition transformer and cable (E04)
  • The ignition electrode: gap, cleanliness, earthing (E04)
  • The gas tap, the gas supply pressure and purging of the gas line (E04)
  • The air and flue duct and the siphon: not blocked and not leaking (E04)
  • The CO2 level at high and low output (E04)

Related codes