Heat exchanger too cold or no flame
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:04), the heat exchanger temperature is too low, because of a badly connected or faulty sensor or water that is not circulating; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E04), the burner has not lit after several start attempts (up to 5): no spark, a spark without a flame, or a flame detected too weakly. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On an Avanta or Aquanta: check that the boiler's gas tap is open; if it is closed, open it.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:04?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:04
The meaning depends on the boiler: find yours below.
No flame detected (After a long period without use, up to 5 start attempts may
No flame formed after the 5th start
More than 5 start attempts without flame formation.
Heat exchanger temperature too low
Heat exchanger temperature within the normal range
The boilers that show this code
What our technician checks
- The heat exchanger sensor's wiring and fitting, replaced if needed (E:04)
- Circulation (direction, pump, valves), bleeding and water pressure (E:04)
- How clean the heat exchanger is, and the boiler type parameter (E:04)
- The ignition transformer and cable (E04)
- The ignition electrode: gap, cleanliness, earthing (E04)
- The gas tap, the gas supply pressure and purging of the gas line (E04)
- The air and flue duct and the siphon: not blocked and not leaking (E04)
- The CO2 level at high and low output (E04)