Heat exchanger too hot or ionisation fault

Breakdown: the boiler is stopped

This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:05), the heat exchanger temperature is too high, because of a badly connected or faulty sensor or water that is not circulating; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E05), the flame is no longer detected properly (ionisation current fault or repeated loss), among other things because of an incorrect CO2 setting. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On a Calenta, Tzerra M or Quinta Pro: check the water pressure. Above 0.8 bar, bleed the radiators; below it, top up with water to about 1.5 bar as the user manual explains.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E:05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E:05

The meaning depends on the boiler: find yours below.

E05

Ionisation fault

Breakdown: the boiler is stopped Avanta Platinum Plus, Avanta Plus
E05

More than 5 times during one heat demand, loss or drop of ionisation.

Breakdown: the boiler is stopped Aquanta, Avanta
E:05

Heat exchanger temperature too high

Breakdown: the boiler is stopped Calenta, Quinta Pro, Tzerra M
E:05

Heat exchanger temperature above the normal range

Breakdown: the boiler is stopped Gas 210 Eco Pro

The boilers that show this code

What our technician checks

  • The heat exchanger sensor's wiring and fitting, replaced if needed (E:05)
  • Circulation (direction, pump, valves), bleeding and water pressure (E:05)
  • How clean the heat exchanger is, and the boiler type parameter (E:05)
  • The CO2 setting on the gas valve unit (E05)
  • The ignition and ionisation electrodes, their connector and cable (E05)
  • The flue gas and air supply ducts (E05)
  • The gas inlet pressure and the gas valve diaphragm (Aquanta)
  • The gas flow at high output (Avanta Plus, Avanta Platinum Plus)

Related codes