Sensor short circuit or return too hot
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M or Quinta Pro (E:02), the flow temperature sensor is short-circuited, and on a Gas 210 Eco Pro it is the heat exchanger sensor; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E02), the water coming back from the system is hotter than the flow water, because of too little water, no circulation, air, a badly connected sensor or reversed wiring. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- On an Avanta or Aquanta: check the water pressure; below 1 bar, top up with water as the user manual explains.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:02
The meaning depends on the boiler: find yours below.
Return temperature >
Return temperature higher than the flow temperature
Flow temperature sensor short-circuited
Short circuit in the flow temperature sensor
Short circuit in the heat exchanger temperature sensor
The boilers that show this code
What our technician checks
- The sensor wiring (E:02)
- How the sensor is fitted and works, replaced if needed (E:02)
- The system water pressure (E02)
- The circulating pump: shaft freed with a screwdriver, wiring, replaced if it still does not run (E02)
- Bleeding the air from the boiler and the system (E02)
- The wiring between the sensors and the control unit (E02)
- The flow and return sensors: 12 to 15 kΩ at 20 to 25 °C (E02)