Parameter unit not found or sensor fault
Breakdown: the boiler is stopped
This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:00), the control unit can no longer find the unit that stores its parameters (PSU), because of a bad connection; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E00), a flow or return temperature sensor is short-circuited, faulty or badly connected. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E:00?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E:00
The meaning depends on the boiler: find yours below.
Flow or return sensor fault
Flow or return sensor error.
Parameter storage unit PSU not found
Parameter storage unit not found
The boilers that show this code
What our technician checks
- The wiring of the PSU parameter unit (E:00)
- The wiring and connection of the flow and return sensors (E00)
- The sensors' resistance with a multimeter: 12 to 15 kΩ at 20 to 25 °C (E00)
- The sensors' protective caps, put back (Avanta Plus, Avanta Platinum Plus)