Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Remeha Fault code Remeha
E:01

Safety parameters wrong or flow too hot

Breakdown: the boiler is stopped

This code does not mean the same on every boiler: on a Calenta, Tzerra M, Quinta Pro or Gas 210 Eco Pro (E:01), the control unit's safety parameters are incorrect, because of a bad connection or a faulty PSU board; on an Avanta, Avanta Plus, Avanta Platinum Plus or Aquanta (E01), the flow water has gone above the maximum temperature, because of too little water, no circulation, air in the system or a drifting sensor. In both cases the boiler locks out and stays off until the cause is removed and it is reset (on a Tzerra M, which has no display, the light on the button then flashes red).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. On an Avanta or Aquanta: check the water pressure; below 1 bar, top up with water as the user manual explains.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E:01?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E:01

The meaning depends on the boiler: find yours below.

E01

Flow temperature > Maximum operating temperature

Breakdown: the boiler is stopped Avanta Plus
E01

Flow temperature >

Breakdown: the boiler is stopped Avanta Platinum Plus
E01

The flow temperature is higher than the maximum set temperature.

Breakdown: the boiler is stopped Aquanta, Avanta
E:01

The safety parameters are wrong

Breakdown: the boiler is stopped Calenta
E:01

Safety parameters incorrect

Breakdown: the boiler is stopped Quinta Pro, Tzerra M
E:01

The safety parameters are not in the right order

Breakdown: the boiler is stopped Gas 210 Eco Pro

The boilers that show this code

What our technician checks

  • The wiring of the control unit (E:01)
  • The PSU board, replaced if faulty (Calenta, Tzerra M, Quinta Pro)
  • The system water pressure, on the pressure gauge (E01)
  • The circulating pump: shaft freed with a screwdriver, wiring, replaced if it still does not run (E01)
  • Bleeding the air from the boiler and the system (E01)
  • The flow and return sensors: 12 to 15 kΩ at 20 to 25 °C (E01)

Related codes