Pressure too low after automatic filling
Breakdown: the boiler is stopped
After automatic filling, the system's water pressure did not rise enough (on the Avanta Ace: minimum pressure not reached after 6 minutes): a water tap closed, a leak, or a fault in the pressure sensor or the automatic filling. On the Calenta Ace, Tzerra Ace, Calenta Ace-Matic, Tzerra Ace-Matic and Avanta Ace it is a lockout: the boiler stops and only starts again once the cause has been removed and the boiler has been reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the main water tap is fully open.
- Look for a visible water leak on the boiler or the system; if there is one, call us.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E02.39?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02.39
The meaning depends on the boiler: find yours below.
Minimum pressure not reached after 6 minutes of automatic filling
Insufficient pressure increase after automatic filling
Low press rise AF
Insufficient pressure rise after auto-fill
What our technician checks
- The main water tap and the filling tap, fully open
- The inlet combination valve, fully open
- Whether the boiler and the system are watertight, and the water pressure
- The pressure sensor and the pressure switch wiring
- The safety valve
- Whether the automatic filling works
- The circuit board, replaced if needed