Flame lost five times
Breakdown: the boiler is stopped
While running, the burner flame went out unintentionally five times (within 24 hours on the Avanta Ace). The boiler locks out for safety and stays off until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E01.04?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E01.04
The meaning depends on the boiler: find yours below.
Flame loss detected five times in 24 hours
Flame loss error
Flame loss error
5x Flame loss err
What our technician checks
- The gas tap, the gas supply pressure and purging the gas line
- The gas valve: operation, setting and calibration
- The air supply and flue gas ducts (blockage)
- Flue gas being drawn back in (recirculation)
- The electrode: connection, wiring and condition
- How clean the heat exchanger is on the flue gas side
- The mains supply voltage