Remeha Fault code Remeha
20

Fan speed too high

Breakdown: the boiler is stopped

On Remeha Gas 310 Eco and Gas 610 Eco boilers, the fan, which draws in the combustion air, runs faster than it should: a setting, the fan cable, the fan or the control unit is the cause. It is a lockout: the boiler stops, the code flashes, and it only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 20?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 20

The meaning depends on the boiler: find yours below.

20

Fan speed too high

Breakdown: the boiler is stopped Gas 310 Eco, Gas 610 Eco

What our technician checks

  • The settings (parameters)
  • The fan cable: fault or poor contact
  • The fan or the control unit, if the fault persists

Related codes