False flame signal detected
Breakdown: the boiler is stopped
The boiler detects a flame while the gas valve is closed: the burner keeps glowing after a badly set combustion (CO2 too high), or the gas valve leaks or stays open, and the boiler locks out with the digits flashing. It only restarts after a reset; on the Gas 210 Eco, code 0.0 (with a dot) is a different fault: the minimum position of the air/gas mixing system (SMI) is above its start position.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 00?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 00
The meaning depends on the boiler: find yours below.
Minimum position of the SMI flag above the start position
Flame simulation
Flame simulation, unjustified flame signal
The boilers that show this code
What our technician checks
- The combustion setting (CO2 too high, burner glowing)
- The ignition/ionisation electrode: gap of 3 to 4 mm
- Whether the gas valve closes tightly, replaced if it leaks
- Gas 210 Eco (code 0.0): the setting of the SMI minimum flag, the wiring and connectors, then the SMI board