Fault codes Elco

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

The code is sometimes followed by a number (6A 227): the code is enough.

Your brand

All codes Elco

1P0 Low water flow reported by the pump
1P1 Flow check 1 failed
1P2 Flow check 3 failed
1P3 Flow check 4 failed
1P9 Dynamic pressure check attempt failed
3P9 Scheduled maintenance due
5P1 No flame (warning 1)
5P2 No flame (warning 2)
5P3 Flame lift (warning)
10 Outdoor temperature sensor fault
20 Boiler temperature sensor fault
26 Common flow temperature sensor fault
28 Flue gas temperature sensor fault
30 Flow temperature sensor 1 fault
32 Flow temperature sensor 2 fault
38 Primary controller flow sensor fault
40 Return temperature sensor fault
46 Cascade return sensor fault
47 Common return sensor fault
50 Hot water sensor 1 fault
52 Hot water sensor 2 fault
54 Hot water primary controller sensor fault
57 Hot water circulation sensor fault
60 Room sensor 1 fault
61 Room unit 1 faulty
62 Room unit 1 of the wrong type
65 Room sensor 2 fault
70 Buffer tank sensor 1 fault
71 Buffer tank sensor 2 fault
72 Buffer tank sensor 3 fault
73 Solar collector sensor 1 fault
74 Solar collector sensor 2 fault
78 Water pressure sensor fault
81 LPB bus short circuit or no connection
82 Two devices with the same LPB address
83 BSB bus short circuit
84 Two devices with the same BSB address
85 BSB radio link error
91 Controller memory (EEPROM) error
92 Fault in the boiler electronics
98 Extension module 1 fault
99 Extension module 2 fault
100 Two clock masters on the LPB bus
101 Overheat on a burner
102 LPB bus clock master without power reserve
103 Communication error or flow check
104 Flow check 2 failed
105 Service due, or a fault on L Plus
106 Flow check failed three times
107 Flow check 5 failed
109 Boiler temperature supervision
110 Safety limiter or flow sensor fault
111 Temperature limiter cut-out
112 Return sensor open or short-circuited
117 Flow sensor 2 or water pressure too high
118 Sensor check or water pressure too low
119 Water pressure switch or burner door thermostat
121 Circuit 1 flow temperature not reached
122 Circuit 2 flow temperature not reached
125 Pump supervision fault
126 Hot water charging supervision
127 Legionella temperature not reached
128 Flame lost during operation
129 Fan or air pressure monitor fault
130 Flue gas temperature too high
131 Burner fault, no cause given
132 Gas pressure or flue gas switch tripped
133 No flame at ignition
140 Dynamic pressure check failed
142 Pump feedback signal open or shorted
143 Pump reports abnormal running
144 Pump reports abnormal stop
145 Pump reports a failure
146 Configuration, internal fault or pump flow
151 Internal burner controller error
152 Parameter setting error
153 Boiler locked by hand
154 Plausibility check failed
160 Fan not reaching its speed
161 Maximum fan speed exceeded
162 Air pressure switch does not close
163 Boiler parameter setup failed
164 Boiler water flow switch open
165 Boiler parameter setup missing
166 Air pressure switch does not open
167 Parameter setup waiting for reset
171 Alarm contact H1 or H4 active
172 Alarm contact H2 or H5 active
173 Alarm contact H6 active
174 Alarm contact H3 or H7 active
178 Heating circuit 1 limit thermostat
179 Heating circuit 2 limit thermostat
180 Chimney sweep function active
181 Controller stop function active
182 Sitherm Pro electrode drift test running
183 Boiler in parameter setting mode
184 Modem function active
185 Screed drying function active
193 Pump monitoring fault after flame on
216 Fault on the boiler
217 Fault on a sensor
241 Solar flow sensor fault
242 Solar return sensor fault
243 Swimming pool temperature sensor fault
270 Controller limit function
303 Circuit board fault 1
304 Too many boiler resets
306 Circuit board fault 2
309 Gas relay check failed
310 Communication error with the control display
317 Mains frequency out of range
320 DHW charging temperature sensor fault
322 Water pressure too high
323 Water pressure too low
324 Same sensor on two BX inputs
325 Same sensor on BX and extension module
326 Same sensor on BX and mixing group
327 Same function on several extension modules
328 Same function on mixing groups
329 Same function on module and mixing group
330 Sensor input BX1 not working
331 Sensor input BX2 not working
332 Sensor input BX3 not working
333 Sensor input BX4 has no function
334 Sensor input BX5 has no function
335 Sensor input BX21 has no function
336 Sensor input BX22 has no function
337 Sensor input BX1 has no function
338 Sensor input BX12 has no function
339 Solar collector pump Q5 not available
340 Solar collector pump Q16 not available
341 Solar collector sensor B6 not available
342 DHW sensor B31 not available
343 Solar integration not available
344 Solar buffer actuator K8 not available
345 Solar pool actuator K18 not available
346 Solid fuel boiler pump Q10 not available
347 Solid fuel boiler comparison sensor not available
348 Solid fuel boiler address error
349 Buffer return valve Y15 not available
350 Buffer tank address error
351 Primary controller or system pump address error
352 Pressureless header address error
353 Common flow sensor B10 missing
371 Heating circuit 3 flow temperature off setpoint
372 Heating circuit 3 limit thermostat
373 Extension module 3 fault
378 Repeated internal fault: retries used up
379 Repeated stray flame signal: retries used up
380 Repeated flame loss: retries used up
381 No flame at ignition: retries used up
383 No further attempt allowed
384 Extraneous flame signal detected
385 Mains voltage too low
386 Fan speed outside the permitted range
388 Hot water sensor not working
420 Bus power supply overload
426 Flue gas damper fault or no feedback
427 Flue gas damper wrongly configured
430 Low dynamic pressure, pump blocked or no signal
431 Primary heat exchanger sensor fault
432 Functional earth not connected
433 Primary heat exchanger too hot
440 No cascade manager detected
441 Missing boiler in the cascade
450 BMS voltage configuration error
451 BMS current configuration error
452 BMS external configuration error
501 No flame detected at ignition
502 False flame detected
504 Flame lost repeatedly
506 Weak flame at high fan speed
603 Air pressure switch open (APS)
612 Burner fan error
730 Buffer tank top sensor fault
731 Buffer tank top temperature too high
732 Buffer tank full charge error