143

Pump reports abnormal running

Breakdown: the boiler is stopped

On a Thision L Plus or Trigon L Plus, the feedback signal of the circulating pump of burner 1 or 2 (the figure shown after the code) shows that the pump is running abnormally. This is a locking fault: the burner stays off until a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 143?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 143

The small number shown beside the code tells which.

143
1

Pump Feedback Abnormal Running

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus
143
2

Pump Feedback Abnormal Running

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus

What our technician checks

  • The circulating pump: operation, noise, damage and leaks
  • The flow rate and modulation of the pump of the burner concerned (diagnostics 24.10 or 24.11)
  • The pump cable and its PWM signal on the control unit
  • The system pressure (plausibility check)
  • The automatic air vent and the venting of the system

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.