DHW charging temperature sensor fault
Breakdown: the boiler is stopped
There is a fault on the sensor that measures the domestic hot water charging temperature (sensor B36). On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 320?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 320
The meaning depends on the boiler: find yours below.
DHW charging temperature sensor error
DHW charging temperature sensor fault
What our technician checks
- The sensor input the DHW charging sensor B36 is assigned to (lines 5930 to 5933 on the boiler, 6040 to 6045 on the extension modules)
- The sensor's resistance, measured with the boiler switched off and as close to the sensor as possible, against the maker's values
- The temperature the controller reads on that input, in the input test (lines 7820 to 7835)
- The software diagnostic code and the fault history (lines 6705 and 6800 onwards)