Elco Fault code Elco
371

Heating circuit 3 flow temperature off setpoint

Breakdown: the boiler is stopped

The flow temperature of heating circuit 3 has stayed too far from its setpoint for too long, and the controller is reporting it. On a Trigon XXL or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 371?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 371

The meaning depends on the boiler: find yours below.

371

Flow temperature 3 (heating circuit 3) supervision

Breakdown: the boiler is stopped Trigon XXL
371

Flow temperature 3 (heating circuit 3) monitoring

Breakdown: the boiler is stopped Trigon S Plus

What our technician checks

  • The alarm delay set for flow 3 (line 6742)
  • The circulation pumps, the water pressure and the absence of air in the heating system
  • The controller settings for heating circuit 3
  • The relay output test (line 7700): the output switches on and its wiring is correct
  • The software diagnostic code and the fault history (lines 6705 and 6800 onwards)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.