Heating circuit 3 flow temperature off setpoint
Breakdown: the boiler is stopped
The flow temperature of heating circuit 3 has stayed too far from its setpoint for too long, and the controller is reporting it. On a Trigon XXL or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 371?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 371
The meaning depends on the boiler: find yours below.
Flow temperature 3 (heating circuit 3) supervision
Flow temperature 3 (heating circuit 3) monitoring
What our technician checks
- The alarm delay set for flow 3 (line 6742)
- The circulation pumps, the water pressure and the absence of air in the heating system
- The controller settings for heating circuit 3
- The relay output test (line 7700): the output switches on and its wiring is correct
- The software diagnostic code and the fault history (lines 6705 and 6800 onwards)