Elco Fault code Elco
193

Pump monitoring fault after flame on

Breakdown: the boiler is stopped

Once the flame is lit, the controller checks that the boiler pump is working, and that check has failed. On a Trigon XXL or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 193?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 193

The meaning depends on the boiler: find yours below.

193

Pump supervision error after flame on

Breakdown: the boiler is stopped Trigon XXL
193

Pump monitoring fault after flame ignition

Breakdown: the boiler is stopped Trigon S Plus

What our technician checks

  • The pump operation and its direction of rotation
  • Air in the pump motor and in the system (venting function)
  • The water flow through the boiler, within the maker's limits
  • On a Trigon S Plus, the flow monitoring (contact H7, line 7874)
  • The water pressure and water quality of the system
  • The software diagnostic code and the fault history (lines 6705 and 6800 onwards)

Related codes