No flame (warning 1)
Blocking: it retries by itself
On a Thision L Plus or Trigon L Plus, burner 1 or 2 (the figure shown after the code) has not detected a flame during an ignition attempt (display: No Flame 1). This is a warning: the boiler tries again by itself, but if ignition fails again, it locks the burner out (code 501).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 5P1?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 5P1
The small number shown beside the code tells which.
No Flame 1
No Flame 1
What our technician checks
- The ignition electrode: condition, wear, resistance of 100 Ω at most
- The detection electrode: ionisation current of at least 4 μA at full load
- The electrode cable and its fuse, if the electrode is damaged
- The static and dynamic gas pressure
- The gas valve and the venturi: damage, corrosion and operation
- The siphon, its dirt trap and the condensate drain