Elco Fault code Elco
441

Missing boiler in the cascade

Breakdown: the boiler is stopped

On a Thision L Plus or Trigon L Plus, in a system of several boilers in cascade, the master boiler can no longer find one of the boilers on the bus. This is a locking fault: it stays on the display until a reset, and if it comes back our technician has to find the cause.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 441?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 441

The meaning depends on the boiler: find yours below.

441

Missing Boiler Detected

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus

What our technician checks

  • The cascade bus cable and its terminals
  • The configuration of each boiler: single, master or numbered slave (parameter 0.2)
  • The number of available boilers and the cascade status (diagnostics 25.4)
  • The cascade symbols on the display: slave connected, on standby or in error