Elco Fault code Elco
342

DHW sensor B31 not available

Breakdown: the boiler is stopped

The controller reports that the domestic hot water sensor B31, used for solar heating, is missing: none of its sensor inputs is set for that sensor. On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 342?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 342

The meaning depends on the boiler: find yours below.

342

DHW sensor B31 not available

Breakdown: the boiler is stopped Trigon XXL
342

Solar DHW sensor B31 missing

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus

What our technician checks

  • The sensor input the DHW sensor B31 is assigned to (lines 5930 to 5933 on the boiler, 6040 to 6045 on the extension modules)
  • The sensor's resistance, measured with the boiler switched off and as close to the sensor as possible, against the maker's values