Elco Fault code Elco
603

Air pressure switch open (APS)

Breakdown: the boiler is stopped

On a Thision L Plus or Trigon L Plus, the air pressure switch (APS), which watches the combustion air, has opened for burner 1 or 2 (the figure shown after the code) and has put the boiler into fault. As a precaution we treat this code as a possible flue problem: the boiler must stay off until our technician has been.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.

Does your boiler show 603?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 603

The small number shown beside the code tells which.

603
1

APS Open

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus
603
2

APS Open

Breakdown: the boiler is stopped Thision L Plus, Trigon L Plus

What our technician checks

  • The differential air pressure switch: switching pressure between 5.0 and 6.5 mbar
  • The pressure switch hoses: condition, tightness and clean connection points
  • The combustion air intake
  • The tightness of the flue
  • The non-return flap under the burner cassette: full closing and free movement
  • The siphon, its dirt trap and the condensate drain