Elco Fault code Elco
384

Extraneous flame signal detected

Breakdown: the boiler is stopped

The boiler sees a flame signal it should not see ("extraneous light" on a Trigon XL, "secondary light" on a Thision S Plus or Trigon S Plus); on a Trigon XL the cause given is a short circuit of the ionisation electrode. The boiler goes into safety lockout and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 384?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 384

The meaning depends on the boiler: find yours below.

384

Extraneous light

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus, Trigon XL

What our technician checks

  • The ionisation electrode and its cable (short circuit)
  • The ionisation current, measured with a multimeter (µA) between the electrode and its connection
  • The ignition electrode (wear, damage), replaced if needed (Thision S Plus, Trigon S Plus)