Extraneous flame signal detected
Breakdown: the boiler is stopped
The boiler sees a flame signal it should not see ("extraneous light" on a Trigon XL, "secondary light" on a Thision S Plus or Trigon S Plus); on a Trigon XL the cause given is a short circuit of the ionisation electrode. The boiler goes into safety lockout and the cause must be removed before it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 384?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 384
The meaning depends on the boiler: find yours below.
Extraneous light
What our technician checks
- The ionisation electrode and its cable (short circuit)
- The ionisation current, measured with a multimeter (µA) between the electrode and its connection
- The ignition electrode (wear, damage), replaced if needed (Thision S Plus, Trigon S Plus)