Dynamic pressure check attempt failed
Blocking: it retries by itself
On a Thision L Plus or Trigon L Plus, an attempt at the dynamic check of the heating water pressure has failed for burner 1 or 2 (the figure shown after the code). This is a warning: the boiler tries again by itself, but if the check fails again, it locks the burner out (code 140).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 1P9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 1P9
The small number shown beside the code tells which.
Dynamic Pressure Check Attempt Failed
Dynamic Pressure Check Attempt Failed
What our technician checks
- The system pressure, to be brought back between 1.5 and 2 bar, then venting
- The water pressure sensor (P1) and the pressure read by the boiler (diagnostics 24.12.2)
- The circulating pump: operation, noise, damage and leaks
- The flow rate and modulation of the pump of the burner concerned (diagnostics 24.10 or 24.11)
- The automatic air vent and the venting of the system
- The system venting cycle (24.9.1)
- The water connections: damage, corrosion and leaks