Boiler parameter setup failed
Breakdown: the boiler is stopped
On a Thision L Plus or Trigon L Plus, the controller reports that the boiler's basic parameter setup is not valid (display: Boiler parametrization KO). This is a locking fault: it stays on the display until a reset, and if it comes back our technician has to find the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 163?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 163
The meaning depends on the boiler: find yours below.
Boiler parametrization KO
What our technician checks
- The boiler type set in the controller (parameter 24.0.9)
- The connection of the boiler sensors (NTC), which the parameter setup waits for (message 164)
- The parameter backup and restore functions (24.9.2 and 24.9.3)
- The boiler control unit (circuit board)