Same sensor on BX and mixing group
Breakdown: the boiler is stopped
The same sensor is set twice, on a BX sensor input of the boiler and for the mixing valve group: this is a mistake in the installation settings. On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 326?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 326
The meaning depends on the boiler: find yours below.
BX / mixing group same sensors
BX / mixing group same sensor
What our technician checks
- The functions set on the BX sensor inputs of the boiler (lines 5930 to 5933)
- The function set for mixing valve group 1 of the boiler (line 6014)