Buffer tank sensor 3 fault
Breakdown: the boiler is stopped
The controller reports a fault of temperature sensor 3 of the system's buffer tank. The boiler goes into safety lockout and the cause must be removed before it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 72?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 72
The meaning depends on the boiler: find yours below.
Buffer storage tank temperature 3 sensor error
Buffer tank temperature sensor 3 fault
What our technician checks
- Buffer tank sensor 3, its cable and its connection
- The setting of the sensor input that takes it (buffer tank sensor B4, B41 or B42, lines 5930 to 5932 on a Thision S Plus or Trigon S Plus)
- The sensor's resistance, measured as close to the sensor as possible and compared with the maker's values