Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Elco Fault code Elco
323

Water pressure too low

Breakdown: the boiler is stopped

The water pressure in the heating system is too low (on a Trigon XL, measured by the sensor on input H3): the circuit is short of water. The manual lists this code among the lockouts: the boiler is reset once the cause is removed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Thision S Plus or Trigon S Plus: check the water pressure on the gauge or with the Info key and, if it is too low, top up as the user manual explains.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 323?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 323

The meaning depends on the boiler: find yours below.

323

Water pressure 3 too low

Breakdown: the boiler is stopped Trigon XL
323

Water pressure too low

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus

What our technician checks

  • The system pressure, filling and venting
  • Trigon XL: the pressure sensor on input H3 and its setting

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.