No flame at ignition
Breakdown: the boiler is stopped
The boiler tried to light its burner but no flame was detected within the safety time; after the attempts allowed (on a Trigon XL, when the repeat counter is exceeded) it goes to safety shutdown. It stops heating until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 133?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 133
The meaning depends on the boiler: find yours below.
Safety time for establishment of flame exceeded
No flame during safety time
Safety time limit for flame combustion exceeded
No flame during the safety time
What our technician checks
- The gas pressure at the boiler
- Air in the gas line, to be purged
- The ignition and ionisation electrodes, their cables and connections
- The ionisation current, measured with a multimeter set to µA
- The combustion values at full and minimum load