Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Elco Fault code Elco
5P3

Flame lift (warning)

Blocking: it retries by itself

On a Thision L Plus or Trigon L Plus, the flame of burner 1 or 2 (the figure shown after the code) has lifted off while running (display: Flame lift 1). This is a warning: the boiler tries again by itself, but if this happens again and again, it locks the burner out (code 504).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 5P3?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 5P3

The small number shown beside the code tells which.

5P3
1

Flame lift 1

Blocking: it retries by itself Thision L Plus, Trigon L Plus
5P3
2

Flame lift 1

Blocking: it retries by itself Thision L Plus, Trigon L Plus

What our technician checks

  • The flame stability, the settings and the burner
  • The O2/CO2 setting and the ionisation current
  • The static and dynamic gas pressure
  • The detection electrode: ionisation current of at least 4 μA at full load
  • The combustion air intake
  • The tightness of the flue

Related codes