Elco Fault code Elco
243

Swimming pool temperature sensor fault

Breakdown: the boiler is stopped

There is a fault on the swimming pool temperature sensor (sensor B13), used when the boiler also heats a pool. On a Trigon XXL, a Thision S Plus or a Trigon S Plus this code is one of the lockouts: the boiler stops and the cause must be removed before it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 243?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 243

The meaning depends on the boiler: find yours below.

243

Swimming pool temperature sensor error

Breakdown: the boiler is stopped Trigon XXL
243

Swimming pool temperature sensor fault

Breakdown: the boiler is stopped Thision S Plus, Trigon S Plus

What our technician checks

  • The sensor input the pool sensor B13 is assigned to (lines 5930 to 5933 on the boiler, 6040 to 6045 on the extension modules)
  • The pool temperature read by the controller (line 8900)
  • The sensor's resistance, measured with the boiler switched off and as close to the sensor as possible, against the maker's values

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.