Fault codes Weishaupt

Type the code your boiler shows: what it means, what you can do, and when a technician is needed.

The code is sometimes followed by a number (6A 227): the code is enough.

Your brand

Your boiler Weishaupt

The model is written on the rating plate, often under the cover.

All codes Weishaupt

01h-02h, 05h-0bh, 0dh-10h, 13h-15h, 17h, 19h-1Ch, 1Eh, 43h, 45h, 50h, 56h, 69h-A0h, A4h-A5h, ACh, b0h-b2h, b9h Internal fault in the burner control box
03h Room too hot or internal fault
04h Too many resets in 15 minutes
0Ch Wrong burner configuration
10x Burner control box fault
11h Supply voltage too low
12h Brief power supply interruption
16h TWI link (VisionBox) faulty
18h Burner stopped: see the detailed code
1dh Electromagnetic interference (EMC)
2x No flame at burner start
40h Speed calibration out of limits
41h Fan speed deviation
42h Speed sensor not connected
44h Burner settings changed without approval
46h Burner motor turning the wrong way
47h Invalid air servomotor type
48h Servomotor tolerance error
49h Servomotor misses its reference point
4Ah Parameter E0 clashes with the coding plug
4x Flame detected outside operation
63h Wrong speed drive curve
65h Servomotor or speed drive tolerance error
67h Flame sensor short circuit
6x Burner servomotor fault
7x Flame lost during operation
8x Burner release contact open
9x Flame lost on stage 2
A2h Safety chain open
A6h Flame simulation or stray light
A7h No flame when the burner starts
A8h Flame lost while the burner runs
A9h Flame lost just after ignition
AAh Air pressure switch not at rest
Abh Air pressure switch does not switch
CCh Oil pressure switch does not switch
CEh Bridge plug no. 15 missing
CFh No start release (X3.14)
Cdh Second air pressure switch does not switch
F1 Extension module link or sensor T1
F10 Lost link to an extension module
F11 Flow water above 105 °C
F12 Flow water above 95 °C
F13 Flue gas too hot, boiler locked out
F14 Flow heating too fast, boiler locked out
F15 Temperature difference too large, boiler locked out
F16 Flue gas temperature too high
F17 Combustion air too hot
F19 Locked out: fast temperature rise or chamber overpressure
F2 Outdoor, tank or T2 sensor faulty
F20 Flame lost at ignition or no solar flow
F21 No flame when the burner starts
F21-1 No flame at burner start (fault)
F21-2 Flame too short at burner start (fault)
F22 Flame lost during operation
F23 False flame detected by the boiler
F24 Burner blocked by an external contact
F25 Flame lost during stabilisation
F29 Hot water or heat exchanger sensor faulty
F3 Module flow sensor faulty
F30 Flow temperature sensor faulty
F31 Flue gas sensor faulty
F32 Low loss header sensor faulty
F33 Outdoor temperature sensor faulty
F34 Hot water sensor faulty
F35 Flow sensor faulty
F36 System water pressure out of range
F37 Water flow or fresh air sensor faulty
F38 Sensor T1 or B10 faulty
F39 Sensor T2 or B11 faulty
F4 Solar return sensor faulty
F40 Built-in pump electronics fault
F41 Gas valve or flue gas flap fault
F42 Built-in pump blocked
F43 Fan speed not reached
F43-1 Fan speed not reached (fault)
F43-2 Fan does not come to a stop
F43-4 Fan communication fault
F43-5 General fan fault
F43-6 Fan: combination with boiler not allowed
F44 Fan fault when at rest
F45 Gas valve out of tolerance
F46 VPT multifunction sensor fault
F47 VPT sensor not compatible or ignition fault
F49 Combustion manager data error
F5 Buffer tank or circulation sensor faulty
F50 Internal electronics error
F51 Boiler data error
F52 Burner data error
F53 Power supply out of tolerance
F54 Fault in the electronics
F55 Memory fault or mains frequency out of range
F56 Ionisation measurement or component test fault
F57 Extension module missing or link lost
F58 Too many resets or faulty reset key
F59 Missing data or internal communication fault
F6 Buffer tank or hot water sensor faulty
F60 Calibration too low or data error
F61 Ionisation signal out of tolerance or BCC missing
F61-1 Flame signal out of tolerance (fault)
F62 Gas valve signal or BCC data fault
F62-1 Gas valve position signal out of tolerance
F63 Flue blocked, SCOT fault or BCC error
F64 Calibration too high, condensate blocked or transfer failed
F65 Calibration too far from previous or BCC error
F66 Combustion calibration failed
F67 Calibration value stored incorrectly
F68 Gas valve offset out of range
F70 BCC data or oil preheating fault
F71 BCC coding key missing
F72 BCC coding key data error
F73 BCC coding key not compatible
F74 BCC update requested
F75 Data error on the BCC coding key
F80 Remote control signal on N1 too low
F81 Remote control signal on N1 too high
F88 Internal electronics error
F90 ChipCom communication fault
F91 No communication between control and combustion manager
F92 CAN bus communication fault
F93 Flash memory communication fault
F94 Modbus communication fault with the VPT sensor
F95 Internal electronics error
F96 VPT sensor data communication fault
F99 Unknown combustion manager fault
Orange/rouge clignotant Low voltage or internal fuse
Rouge scintillant OCI mode active, not used
Rouge/orange clignotant avec pause Supply voltage too high
Vert clignotant Weak flame signal
Vert/rouge clignotant Stray light before the heat demand
W1 Room humidity too high
W10 Water flow through the boiler too low
W100 Heating circuit flow sensor faulty
W102 Local outdoor sensor (T1) faulty
W11 Heating circuit emergency stop
W110 Heating circuit overheat protection triggered
W1101-1112 Lost link to a WEM-SG display unit
W111 Emergency stop via input H1
W12 Flow water above 95 °C
W1201-1212 Lost link to a combustion manager
W1302-1325 Lost link to a heating circuit module
W14 Flow water heating up too fast
W1401 Lost link to the solar module
W15 Temperature difference too large
W1501-1532 Lost link to a room unit 2
W16 Flue gas temperature too high
W160 Room unit temperature sensor faulty
W1601-1632 Lost link to a room sensor
W161 Room unit humidity sensor faulty
W17 Flow-return gap or combustion air too hot
W170 Room humidity below the minimum
W1701-1732 Lost link to a room unit 1
W171 Room humidity above the maximum
W18 Gap between the two flow sensors
W1800 Lost link to the cascade module
W19 Fast temperature rise or combustion chamber overpressure
W1902-1925 Lost link to a hot water module
W2 Room humidity too low
W20 Flame lost during ignition
W21 No flame when the burner starts
W21-1 No flame at burner start (warning)
W21-2 Flame too short at burner start (warning)
W22 Flame lost during operation
W24 Burner blocked by an external contact (H2)
W25 Flame lost or condensate alarm
W27 Gas pressure too low or sensor faulty
W28 Pressure sensor or return sensor faulty
W3 SD card or USB stick not found
W30 Boiler sensor faulty
W32-1 Hydraulic separator sensor faulty
W32-2 Plate heat exchanger sensor faulty
W33 Outdoor temperature sensor faulty
W34 Hot water sensor B3 faulty
W35 Hot water sensor faulty (loop or outlet)
W36 System water pressure too low
W37 Hot water flow sensor faulty
W39 Lower buffer tank sensor faulty
W40 Built-in pump reports a fault
W42 No control signal for the pump
W42-1 Internal pump communication fault
W42-2 Internal circulation pump blocked
W42-3 Internal pump electrical fault
W43 Fan speed out of range
W43-1 Fan speed not reached (warning)
W43-3 Fan supply voltage too low
W46-… VPT multifunction sensor faulty
W48 Air in the heating system
W53 Power supply out of tolerance
W61 Abnormal flame signal or coding plug missing
W61-1 Flame signal out of tolerance (warning)
W62 Gas valve position out of tolerance
W63 SCOT system fault or flue blocked
W64 Condensate drain blocked
W66 Combustion calibration failed
W69 Combustion unstable at part load
W7 Hot water circulation sensor inactive
W8 Hot water module source sensor faulty
W80 External control: weak signal or lost link
W81 External control: signal too high or link lost
W82 Connection lost with module no. 2
W83 Connection lost with module no. 3
W84 Connection lost with module no. 4
W85 Connection lost with module no. 5
W85-1 USB stick write test failed
W85-2 USB stick formatting failed
W85-3 USB stick initialisation failed
W85-4 USB stick not compatible
W85-5 USB stick not found
W86 Connection lost with module no. 6
W87 Connection lost with module no. 7
W88 Connection lost with module no. 8
W89 Remote setpoint signal missing
W90 Bus device not recognised
W92-1 Heating circuit module EM-HK not on bus
W92-2 Room unit or room sensor not on bus
W96-1 Communication fault between WEP-ZE and VPT
W96-2 Modbus link lost between WEP-ZE and VPT
bAh Stray light seen at start-up
bbh Burner stopped by contact X3:7
d1h Servomotor connection fault
d2h Too many remote resets
d4h External voltage or internal fault
nocon Control panel has lost the electronics