Weishaupt Fault code Weishaupt
W25

Flame lost or condensate alarm

Blocking: it retries by itself

On a WTC-GW or WTC-GB B series boiler and a WTC-GW C series boiler, the flame goes out just after ignition, while it is stabilising; on a WTC-OB the condensate lift pump is in alarm or the float switch in the boiler's base tray has detected liquid, and the burner stops. It is a warning that does not lock the boiler: an occasional flame loss (strong wind) needs nothing, but a code that keeps coming back needs our technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show W25?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code W25

The meaning depends on the boiler: find yours below.

W25

Flame loss during the stabilisation time

Blocking: it retries by itself WTC-GW C (WEP), WTC-GW/GB B (WEM)
W25

Condensate lift pump alarm / The float switch has tripped

Blocking: it retries by itself WTC-OB (WCM-OB)

What our technician checks

  • The gas supply pressure
  • The ionisation electrode, replaced if needed
  • The burner surface, cleaned or replaced, and clean combustion air
  • Flue tightness and the condensate drain
  • The flue gas shut-off device, replaced if needed
  • The condensate lift pump (WTC-OB)
  • The base tray, cleaned or emptied, and the float switch (WTC-OB)

Related codes