Flame lost or condensate alarm
Blocking: it retries by itself
On a WTC-GW or WTC-GB B series boiler and a WTC-GW C series boiler, the flame goes out just after ignition, while it is stabilising; on a WTC-OB the condensate lift pump is in alarm or the float switch in the boiler's base tray has detected liquid, and the burner stops. It is a warning that does not lock the boiler: an occasional flame loss (strong wind) needs nothing, but a code that keeps coming back needs our technician.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W25?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W25
The meaning depends on the boiler: find yours below.
Flame loss during the stabilisation time
Condensate lift pump alarm / The float switch has tripped
What our technician checks
- The gas supply pressure
- The ionisation electrode, replaced if needed
- The burner surface, cleaned or replaced, and clean combustion air
- Flue tightness and the condensate drain
- The flue gas shut-off device, replaced if needed
- The condensate lift pump (WTC-OB)
- The base tray, cleaned or emptied, and the float switch (WTC-OB)