Ionisation signal out of tolerance or BCC missing
Breakdown: the boiler is stopped
On a WTC-GW or WTC-GB B series boiler and on a Thermo Condens WTC-A, the signal of the ionisation electrode, used to control combustion, deviates too far from the expected value, for example when the gas type is set wrongly; on a WTC-OB oil boiler, the BCC coding key is not fitted. The boiler locks out and stops heating until our technician has checked the electrode, the gas setting or the BCC key.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F61?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F61
The meaning depends on the boiler: find yours below.
Ionisation signal out of tolerance
Ionisation signal drifts too far from the setpoint
BCC coding plug not in place
What our technician checks
- The ionisation electrode and its cable (cable resistance)
- The gas type setting (boiler and gas valve)
- The boiler electronics if the fault keeps coming back
- The BCC coding key, to be fitted (WTC-OB)