No flame when the burner starts
Breakdown: the boiler is stopped
At start-up the burner fails to form a flame: on gas on a WTC-GW or WTC-GB B series boiler and on a Thermo Condens WTC-A (which gives up after 5 ignition attempts), on oil on a WTC-OB boiler. The boiler then locks out and stops heating; on a WTC-GW or WTC-GB B series boiler the same code can also point to a fault in the controller of a connected solar module, unrelated to the burner.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F21?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F21
The meaning depends on the boiler: find yours below.
Combustion manager: No flame formation when the burner starts / Solar EM: Differential controller fault
No flame formation at start-up
No flame formation when the burner starts
What our technician checks
- The gas supply: connection pressure, gas valve and its cable, maximum gas pressure switch
- The ionisation electrode, the ignition electrode and its cable
- The ignition unit (ignition transformer on the WTC-OB)
- The burner, to be cleaned, and the cleanliness of the combustion air
- The flame formation time and the gas setting at ignition
- The tightness and clear passage of the flue, and the condensate drain
- On the WTC-OB: the oil supply and pump, the solenoid valves, the nozzle and the flame sensor
- With a solar module (WTC-GW, WTC-GB B series): the control differential between sensors T2 and T3