Flow-return gap or combustion air too hot
Blocking: it retries by itself
On a WTC-GW or WTC-GB B series boiler and a WTC-GW C series boiler, the gap between the water going out to the heating and the water coming back is too large and the boiler has stopped for at least 3 minutes several times in a row; on a WTC-OB the combustion air drawn in by the burner is too hot. It is a warning that clears by itself, but a WTC-OB locks out (F17) after repeated warnings.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W17?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W17
The meaning depends on the boiler: find yours below.
Temperature differential flow/return too large
Combustion air temperature too high (after several alarms, the system…
What our technician checks
- The water flow through the boiler, increased if needed
- The heat demand (heating curve), lowered if needed
- The maximum heating output (parameter 2.1.2 on the B series, 3.1.2 on the C series)
- The thermal insulation (WTC-OB)
- The combustion air sensor, replaced if needed (WTC-OB)
- The sensor wiring, in case two sensors are swapped (WTC-OB)