Flame lost during operation
Breakdown: the boiler is stopped
The flame goes out while the burner is running, with the same meaning on a WTC-GW C series boiler (gas) and on a WTC-OB (oil); on the WTC-OB this fault follows five W22 warnings, and on the WTC-GW an occasional flame loss, for example in strong wind at the flue outlet, needs no action. This is a fault: the boiler locks out for safety and only restarts after it is unlocked.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F22?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F22
The meaning depends on the boiler: find yours below.
Flame loss during operation
Flame loss during operation (see also W22)
What our technician checks
- The gas supply pressure (WTC-GW)
- The oil supply, measured with a gauge on the oil pump, and the oil pump (WTC-OB)
- The ionisation electrode (WTC-GW), or the flame sensor and its sight tube (WTC-OB)
- The burner surface, cleaned or replaced, and clean combustion air (WTC-GW)
- The nozzle and its spacing, the mixing device, the flame tube and the burner setting (WTC-OB)
- Flue system tightness (room-sealed operation) and a clear flue path
- The condensate drain
- The isolating valves, replaced if needed (WTC-GW)