Burner blocked by an external contact
Breakdown: the boiler is stopped
A device connected to a boiler input (H1 or H2), for example the safety thermostat of an underfloor heating circuit or of a condensate lift pump, blocks the burner: burner lock function on a WTC-GW or WTC-GB B series boiler, emergency off on a WTC-GW C series boiler, underfloor heating safety thermostat on a Thermo Condens WTC-A. The boiler does not heat while that contact blocks it, and the code clears by itself once the contact is released (on the WTC-A, once the floor temperature has dropped).
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F24?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F24
The meaning depends on the boiler: find yours below.
Burner lockout function activated
The underfloor heating safety thermostat at input H2 has switched off the boiler
Emergency mode OFF
What our technician checks
- The devices connected to boiler inputs H1 and H2
- The function set for input H1 or H2
- On the WTC-A: the mixing valve, the flow temperature set point and the underfloor heating pump