Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Weishaupt Fault code Weishaupt
F24

Burner blocked by an external contact

Breakdown: the boiler is stopped

A device connected to a boiler input (H1 or H2), for example the safety thermostat of an underfloor heating circuit or of a condensate lift pump, blocks the burner: burner lock function on a WTC-GW or WTC-GB B series boiler, emergency off on a WTC-GW C series boiler, underfloor heating safety thermostat on a Thermo Condens WTC-A. The boiler does not heat while that contact blocks it, and the code clears by itself once the contact is released (on the WTC-A, once the floor temperature has dropped).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F24?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F24

The meaning depends on the boiler: find yours below.

F24

Burner lockout function activated

Breakdown: the boiler is stopped WTC-GW/GB B (WEM)
F24

The underfloor heating safety thermostat at input H2 has switched off the boiler

Breakdown: the boiler is stopped Thermo Condens WTC-A (WCM)
F24-…

Emergency mode OFF

Breakdown: the boiler is stopped WTC-GW C (WEP)

What our technician checks

  • The devices connected to boiler inputs H1 and H2
  • The function set for input H1 or H2
  • On the WTC-A: the mixing valve, the flow temperature set point and the underfloor heating pump

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.