Flame lost during ignition
Blocking: it retries by itself
On a WTC-GW or WTC-GB B series boiler, the flame goes out while the burner is lighting (safety time). It is a warning: the boiler does not lock out, but if the code comes back, our technician needs to check the gas supply and the burner.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W20?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W20
The meaning depends on the boiler: find yours below.
Flame loss during the safety time
What our technician checks
- The gas supply pressure
- The ionisation electrode, replaced if needed
- The burner surface, cleaned or replaced, and clean combustion air
- The flue, its tightness and clear passage, and the condensate drain
- The start and ignition gas quantity settings (parameters 2.3.5 and 2.3.1), keeping the CO content in check
- The flue gas shut-off device, replaced if needed
- The gas valve unit, replaced if needed