Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Weishaupt Fault code Weishaupt
W36

System water pressure too low

Blocking: it retries by itself

The heating water pressure is below the warning threshold (on a WTC-GW C series boiler, outside the allowed range): the boiler keeps heating down to 0.5 bar, stops below that (F36) and restarts by itself when the pressure rises again; a Thermo Condens WTC 45-A or 60-A already stops below 1 bar, and there the same code also reports that the heat exchanger temperature switch has tripped. It is a warning: the system has to be brought back to the right pressure and the cause found, which our technician does.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show W36?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code W36

The meaning depends on the boiler: find yours below.

W36

System pressure too low

Blocking: it retries by itself WTC-GW/GB B (WEM)
W36

System pressure outside the permitted range

Blocking: it retries by itself WTC-GW C (WEP)
W36

Water pressure too low / The safety temperature of the heating body has tripped, cause

Blocking: it retries by itself Thermo Condens WTC-A (WCM)
W36

System pressure too low (see parameter 39)

Blocking: it retries by itself WTC-OB (WCM-OB)

What our technician checks

  • The system pressure, topped up if needed (1.2 bar on the Thermo Condens WTC 45-A or 60-A)
  • The minimum pressure warning threshold for a rooftop boiler room (parameter 2.2.7 on the B series, 3.2.8 on the C series)
  • The heat exchanger temperature switch, to be unlocked by hand (red button) (Thermo Condens WTC 45-A, 60-A)
  • Circulation in the boiler and descaling the heat exchanger on the water side (Thermo Condens WTC 45-A, 60-A)

Related codes