System water pressure too low
Blocking: it retries by itself
The heating water pressure is below the warning threshold (on a WTC-GW C series boiler, outside the allowed range): the boiler keeps heating down to 0.5 bar, stops below that (F36) and restarts by itself when the pressure rises again; a Thermo Condens WTC 45-A or 60-A already stops below 1 bar, and there the same code also reports that the heat exchanger temperature switch has tripped. It is a warning: the system has to be brought back to the right pressure and the cause found, which our technician does.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show W36?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code W36
The meaning depends on the boiler: find yours below.
System pressure too low
System pressure outside the permitted range
Water pressure too low / The safety temperature of the heating body has tripped, cause
System pressure too low (see parameter 39)
What our technician checks
- The system pressure, topped up if needed (1.2 bar on the Thermo Condens WTC 45-A or 60-A)
- The minimum pressure warning threshold for a rooftop boiler room (parameter 2.2.7 on the B series, 3.2.8 on the C series)
- The heat exchanger temperature switch, to be unlocked by hand (red button) (Thermo Condens WTC 45-A, 60-A)
- Circulation in the boiler and descaling the heat exchanger on the water side (Thermo Condens WTC 45-A, 60-A)