Weishaupt Fault code Weishaupt
F61-1

Flame signal out of tolerance (fault)

Breakdown: the boiler is stopped

On a WTC-GW C series boiler, the signal of the ionisation electrode, which watches the flame and controls combustion, is outside the permitted values. This is a fault: the boiler locks out if it can no longer run safely, and the display then offers to unlock it.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F61-1?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F61-1

The meaning depends on the boiler: find yours below.

F61-1

Ionisation signal out of tolerance

Breakdown: the boiler is stopped WTC-GW C (WEP)

What our technician checks

  • The ionisation electrode and its cable, replaced if needed
  • The SCU combustion manager, replaced if the fault returns after unlocking