Weishaupt Fault code Weishaupt
W19

Fast temperature rise or combustion chamber overpressure

Blocking: it retries by itself

On a WTC-GW or WTC-GB B series boiler and a WTC-GW C series boiler, the flow water heats up too fast and the boiler stops to protect its heat exchanger; on a WTC-OB the pressure in the combustion chamber is too high and the boiler stops. It is a warning that clears by itself, but if it happens several times in a row (3 times on a WTC-OB), the boiler locks out with code F19.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Do not reset the boiler: call us.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show W19?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code W19

The meaning depends on the boiler: find yours below.

W19

Flow temp. (VPT) rises too quickly (gradient)

Blocking: it retries by itself WTC-GW/GB B (WEM)
W19

Flow temp. VPT rises too quickly (gradient)

Blocking: it retries by itself WTC-GW C (WEP)
W19

Combustion chamber pressure too high (after 3 alarms, the system locks out with F19)

Blocking: it retries by itself WTC-OB (WCM-OB)

What our technician checks

  • The heat exchanger, cleaned if needed (WTC-OB)
  • The flue and the condensate drain (WTC-OB)
  • The combustion chamber pressure sensor, replaced if needed (WTC-OB)
  • Flame stability and the mixing chamber pressure (WTC-OB)