Weishaupt Fault code Weishaupt
F66

Combustion calibration failed

Breakdown: the boiler is stopped

The boiler could not carry out its combustion (SCOT) calibration, on a WTC-GW or WTC-GB B series boiler, a WTC-GW C series boiler or a Thermo Condens WTC-A: for example for lack of heat demand, because the flame forms too slowly, or after a flame loss during operation (alarm W22). The boiler locks out and stops heating until our technician has found the cause.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F66?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F66

The meaning depends on the boiler: find yours below.

F66

Calibration could not be carried out

Breakdown: the boiler is stopped WTC-GW/GB B (WEM)
F66

Calibration failed

Breakdown: the boiler is stopped WTC-GW C (WEP)
F66

Calibration was not carried out despite the request

Breakdown: the boiler is stopped Thermo Condens WTC-A (WCM)

What our technician checks

  • The heat demand during calibration
  • The preceding W22 alarm (flame loss)
  • The ionisation electrode and its cable
  • The burner, to be cleaned
  • The flame formation time and the ignition settings
  • A 100 % calibration if the gas quality has changed (WTC-A)