VPT multifunction sensor fault
Breakdown: the boiler is stopped
The VPT multifunction sensor, which measures flow, pressure and water temperatures in the boiler, reports a fault; this code exists on the WTC-GW and WTC-GB B series. The cause can be air in the system, too low a pressure or the sensor itself: the boiler locks out if it can no longer run safely, and our technician has to bleed the system or check the sensor.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F46?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F46
The meaning depends on the boiler: find yours below.
VPT multifunction sensor fault
What our technician checks
- Bleeding the system (heating and hot water circuits)
- Bleeding the boiler on the water side (automatic venting programme)
- The system pressure, to be raised
- An air separator to be fitted on the system
- The VPT sensor and its connections, replaced if needed