Weishaupt Fault code Weishaupt
6x

Burner servomotor fault

Breakdown: the boiler is stopped

On a two-stage WL10 or WL20 Z oil burner (W-FM 10 control box), the servomotor did not reach the set position within 10 seconds: connector unplugged, faulty servomotor, limit switches wrongly set, or air damper or angle drive jammed. The burner is locked out (red light button) and does not restart by itself; you read this code by counting 6 red flashes after pressing the button for 5 seconds.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 6x?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 6x

The meaning depends on the boiler: find yours below.

6x

Actuator fault

Breakdown: the boiler is stopped W-FM 10

What our technician checks

  • The servomotor connector
  • The servomotor, replaced if faulty
  • The position of the limit switches
  • Free movement of the air damper and the angle drive

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.