Flame lost during operation
Breakdown: the boiler is stopped
On a WL5, WL10 or WL20 oil burner, the flame went out during operation (on the two-stage Z models with a W-FM 10 control box: on stage 1, stage 2 giving 9 flashes): air leak or hard suction in the oil supply, dirty nozzle, burner setting or flame sensor. The burner is locked out (red light button) and does not restart by itself; you read this code by counting 7 red flashes after pressing the button for 5 seconds.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 7x?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 7x
The meaning depends on the boiler: find yours below.
Flame loss during operation
Flame loss during operation (stage 1)
The boilers that show this code
What our technician checks
- The oil supply: air leak, too much suction vacuum
- The nozzle, to be replaced
- The burner setting and the flame sensor current
- The flame sensor: cleaned, or replaced if faulty
Related codes
From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.