Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Weishaupt Fault code Weishaupt
8x

Burner release contact open

Breakdown: the boiler is stopped

The burner's control box did not get its release signal: on a WL5, WL10 or WL20 oil burner with a W-FM 05 control box, the servomotor limit switch does not close or a bridging plug is missing (no. 2 on X3:2 or no. 12 on X3:12); on a two-stage Z model (W-FM 10 control box), only bridging plug no. 12 is concerned. The burner is locked out (red light button) and does not restart by itself; you read this code by counting 8 red flashes after pressing the button for 5 seconds.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 8x?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 8x

The meaning depends on the boiler: find yours below.

8x

Release contact error

Breakdown: the boiler is stopped W-FM 05, W-FM 10

The boilers that show this code

What our technician checks

  • The servomotor and its limit switch, replaced if faulty (W-FM 05)
  • Bridging plug no. 2 on contact X3:2 (W-FM 05)
  • Bridging plug no. 12 on contact X3:12

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.