Burner release contact open
Breakdown: the boiler is stopped
The burner's control box did not get its release signal: on a WL5, WL10 or WL20 oil burner with a W-FM 05 control box, the servomotor limit switch does not close or a bridging plug is missing (no. 2 on X3:2 or no. 12 on X3:12); on a two-stage Z model (W-FM 10 control box), only bridging plug no. 12 is concerned. The burner is locked out (red light button) and does not restart by itself; you read this code by counting 8 red flashes after pressing the button for 5 seconds.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 8x?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 8x
The meaning depends on the boiler: find yours below.
Release contact error
The boilers that show this code
What our technician checks
- The servomotor and its limit switch, replaced if faulty (W-FM 05)
- Bridging plug no. 2 on contact X3:2 (W-FM 05)
- Bridging plug no. 12 on contact X3:12
Related codes
From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.