No flame at burner start
Breakdown: the boiler is stopped
On a WL5, WL10 or WL20 oil burner, no flame appeared before the end of the safety time at start-up: oil not arriving, blocked nozzle, ignition, solenoid valve or flame sensor fault. The burner is locked out (red light button) and does not restart by itself; you read this code by counting 2 red flashes after pressing the button for 5 seconds.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 2x?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 2x
The meaning depends on the boiler: find yours below.
No flame, end of the safety time
The boilers that show this code
What our technician checks
- The oil supply (air leak), the foot valve and the shut-off valve
- The pre-filter and the oil pump (seized or faulty)
- The nozzle, its distance setting and the mixing pressure
- The ignition electrodes: cleanliness, gap, insulator
- The ignition cable and the ignition transformer
- The solenoid valve coil
- The flame sensor and the burner setting
- The burner motor and its capacitor