Weishaupt Fault code Weishaupt
18h

Burner stopped: see the detailed code

Breakdown: the boiler is stopped

On a WL30 or WL40 oil burner (W-FM 25 control box), the burner has stopped and the second detailed code (keys [+] and [-] together) gives the reason: stop by PC software or Off function used (A7h), no key pressed for 30 minutes in setting mode (A6h), bus address or bus link (A1h, A9h, EEh), configuration (A5h, C1h, EFh), EEPROM memory (A8h, E1h to E7h) or internal fault (01h to 1Bh). The burner is locked out and the code flashes on the display.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 18h?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 18h

The small number shown beside the code tells which.

18h

Shutdown by PC software

Breakdown: the boiler is stopped W-FM 25
18h
01h-1Bh

Internal appliance fault

Breakdown: the boiler is stopped W-FM 25
18h
A1h

Incorrect bus address

Breakdown: the boiler is stopped W-FM 25
18h
A5h

Incorrect configuration at output B4

Breakdown: the boiler is stopped W-FM 25
18h
A6h

In setting mode, no button was pressed for 30 minutes

Breakdown: the boiler is stopped W-FM 25
18h
A7h

The Stop function has been activated

Breakdown: the boiler is stopped W-FM 25
18h
A8h

No comparison values in the EEPROM

Breakdown: the boiler is stopped W-FM 25
18h
A9h

No bus connection

Breakdown: the boiler is stopped W-FM 25
18h
C1h

O2 control operating mode not permitted

Breakdown: the boiler is stopped W-FM 25
18h
E1h-E7h

Comparison values in the EEPROM incorrect

Breakdown: the boiler is stopped W-FM 25
18h
EEh

Communication interrupted to the W-FM 25

Breakdown: the boiler is stopped W-FM 25
18h
EFh

Extension module for the W-FM 25 not compatible

Breakdown: the boiler is stopped W-FM 25

What our technician checks

  • The bus address and the bus link (A1h, A9h)
  • The configuration of output B4 (A5h)
  • The operating mode of the O2 control (C1h)
  • The version of the extension module (EFh)
  • The combustion manager, replaced if the internal fault comes back after a brief power cut and a reset (01h to 1Bh)

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.