Weishaupt Fault code Weishaupt
A9h

Flame lost just after ignition

Breakdown: the boiler is stopped

The oil burner lit, but the flame went out during the stabilisation time, just after ignition. For safety the burner has locked out: the boiler does not heat until the burner is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show A9h?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A9h

The meaning depends on the boiler: find yours below.

A9h

Flame loss during the stabilisation time

Breakdown: the boiler is stopped W-FM 25

What our technician checks

  • The oil nozzles, replaced if needed
  • The setting of the ignition electrodes
  • The ignition transformer, replaced if needed
  • The oil solenoid valve coil and its wiring, replaced if needed
  • The flame sensor and its cable, replaced if needed
  • The mixing chamber pressure, reduced if needed
  • The burner setting
  • The combustion manager, replaced as the last step

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.