Flame too short at burner start (warning)

Blocking: it retries by itself

On a WTC-GW C series boiler, a flame formed briefly when the burner started but was gone at the end of the safety time, and the boiler makes a new start by itself. This is a warning: the boiler does not lock out and the message clears by itself once the cause is removed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show W21-2?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code W21-2

The meaning depends on the boiler: find yours below.

W21-2

Combustion manager: No flame formation when the burner starts

Blocking: it retries by itself WTC-GW C (WEP)

What our technician checks

  • The gas supply pressure (flow monitor)
  • The ionisation electrode, replaced if needed
  • The burner surface, cleaned or replaced
  • Clean combustion air, free of impurities
  • Flame formation time, ignition settings and the gas valve calibration value
  • Flue system tightness (room-sealed operation) and a clear flue path
  • The condensate drain
  • The isolating valves, replaced if needed