Gas valve signal or BCC data fault
Breakdown: the boiler is stopped
On a WTC-GW or WTC-GB B series boiler and on a Thermo Condens WTC-A, the position signal of the gas valve (or the fan) is out of tolerance, for example because of the flue, the condensate drain, too low a gas pressure or the gas type setting; on a WTC-OB oil boiler, the data of the BCC coding key are in error. The boiler locks out and stops heating until our technician has found the cause.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F62?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F62
The meaning depends on the boiler: find yours below.
Gas valve or turbo motor position signal out of tolerance
The position signal of the gas control is outside the tolerance band
BCC data error
What our technician checks
- The ionisation electrode
- The flue tightness and no recirculation of flue gas
- The condensate drain
- The gas connection pressure
- The gas type setting
- The fan, replaced if needed
- The BCC coding key and its data transfer (WTC-OB)